GeoHC Utility Margin Calculator

Did you know that a Geothermal Heating and Cooling (GeoHC) installation in your service territory not only saves the member/consumer money each month, but also gives multiple savings and benefits to the utility itself?

GeoHC technology is uniquely suited to help meet many of the challenges facing electric utilities today.

  • Peak Demand Issues caused by extreme weather events, nationwide electrification efforts, and the rise of large-scale energy consumers like data centers.
  • Need for more capacity on the grid to meet growing demand.
  • Rising costs of power generation that gets passed down to the consumer.

Geothermal Heating and Cooling account for roughly 60% of the energy consumed in a building (electric systems only). Unlike other HVAC technologies, GeoHC can meet this need and not become a burden to the grid when it matters the most.

The Utility Margin Calculator helps demonstrate the value each unit adds, showing you that a strong installation program is a win-win for everyone.

Below are three versions of the calculator that will walk you through the process of understanding just how powerful GeoHC technology is when deployed in mass.

Quick Estimate

Enter the number of GeoHC units to see a simplified estimate of annual demand savings and projected utility margins.

$12/kW
4.0
4.6
2.0
Please enter a number greater than or equal to 1.

Quick Estimate Results

Peak Demand Reduction
0 kW
Annual Demand Savings
$0
Total Annual Margins
$0
30 Yr. New Margins
$0

This simple calculator allows the user to get a valuable preview of how impactful even one ground source heat pump system can be on a utility’s financial situation and grid. No information other than the number of units already installed in your service territory is needed and you will see the benefits to be gained from demand savings and increased revenues. The calculations used to generate these numbers are based on averages of demand costs throughout the nation.

For a more accurate calculation that uses your own utility’s numbers, go to the Level 2 Calculator. 

Utility Margin Calculator – Level 2

4.0
4.6
2.0
Annual Peak Demand Reduction
1 Unit 2.6 kW
500 Units 1,300 kW
1,000 Units 2,600 kW
2,000 Units 5,200 kW

Enter information that is specific to your utility and its GeoHC program.

New Margins

Projected utility margin growth across deployment scenarios.

150010002000
New 10 Yr. Margin$0$0$0$0
New 20 Yr. Margin$0$0$0$0
New 30 Yr. Margin$0$0$0$0

Annual Demand Cost Reduction

Comparison of current demand cost and demand cost with GeoHC across deployment scenarios.

150010002000
Current Demand Cost$0$0$0$0
Demand Cost with GeoHC$0$0$0$0

30 Year Demand Cost Reduction

Long-term demand cost impact comparing current demand cost, GeoHC demand cost, and total savings.

150010002000
Current Demand Cost$0$0$0$0
Demand Cost with GeoHC$0$0$0$0
Savings$0$0$0$0

This calculator is more advanced than the simple version. Instead of entering the number of units installed, you will enter information that is specific to your utility and its GeoHC program. The resulting graphs will demonstrate the value each GeoHC unit has in demand savings, increased revenue, and overall margin effects. Instead of relying on national averages, you are seeing the impact on your utility using your actual numbers.

If you want to see how you can pay for this program annually, go to the Level 3 Calculator.

If you wish to get more information about these calculators, how they work, or how you can use them to help enhance your GSHP program, please reach out to the Geothermal Exchange Organization.

Utility Margin Calculator – Level 3

4.0
4.6
2.0
Load Factor Improvement Rider
0.0050
Annual Peak Demand Reduction
1 Unit 2.6 kW
500 Units 1,300 kW
1,000 Units 2,600 kW
2,000 Units 5,200 kW

Enter information that is specific to your utility and its GeoHC program.

Annual total kilowatt-hours sold by the utility. Enter whole numbers without commas.
Estimated annual investment into the GeoHC incentive program. Enter whole numbers without commas.

New Margins

Projected utility margin growth across deployment scenarios.

150010002000
New 10 Yr. Margin$0$0$0$0
New 20 Yr. Margin$0$0$0$0
New 30 Yr. Margin$0$0$0$0

Annual Demand Cost Reduction

Comparison of current demand cost and demand cost with GeoHC across deployment scenarios.

150010002000
Current Demand Cost$0$0$0$0
Demand Cost with GeoHC$0$0$0$0

30 Year Demand Cost Reduction

Long-term demand cost impact comparing current demand cost, GeoHC demand cost, and total savings.

150010002000
Current Demand Cost$0$0$0$0
Demand Cost with GeoHC$0$0$0$0
Savings$0$0$0$0

This is the complete version of the GeoHC – Utility Margin Calculator. It requires all the information requested in the Level 2 Calculator with a slight addition…the total amount of kWhs sold annually and the amount of investment you have made (or will make) in your incentive program annually. The purpose of this calculator is to show one method of paying for your program. This ‘rate-rider’ method is based on the same program used at many cooperatives for various purposes and it allows the user to completely fund the GeoHC program annually or for however long you desire. This is not the only method of funding, but rather one that has proven highly successful.

If you wish to get more information about these calculators, how they work, or how you can use them to help enhance your GSHP program, please reach out to the Geothermal Exchange Organization.

The three calculators shown are best suited for distribution level electric utilities. G&T utilities have other variables and goals that are not necessarily reflected in the inputs and results of the calculators.

The use of these calculators is meant to demonstrate the possibilities inherent in promoting a robust geothermal heat pump program in an electric utility’s service territory. To keep the process simple, some assumptions are made in the variables used in the calculations, as well as averages and generalizations in industry data and utility situations.

Contact the Geoexchange team for a precise evaluation of how GeoHC can impact your utility.

Glossary of Utility Terms

Watt: A unit of electric power

Kilowatt: 1,000 watts or 1 kilowatt. The standard unit of energy used to bill a customer who consumes electricity.

Horsepower: 1 horsepower = 746 watts or .746 kilowatts

Kilowatt-hour: 1,000 watts for 1 hour = 1 kilowatt hour on the meter. (Example; 100 horsepower equals 100 X .746 = 74.60 kilowatts.  74.60 x 1 hour = 74.60 Kilowatt Hours consumed for one hour of operation.                                          
Another example: A 100-watt light equals 1/10th or 0.10 Kilowatts 1 light at .10 kilowatts operating for 10 hours would consume 1 Kilowatt Hour of electricity.

Megawatt: 1,000 KW or 1,000,000 watts

Demand: The amount of energy needed to be produced to operate any electrical load at any given time expressed in terms of Kilowatt Demand.

Ton: A unit of heating and cooling capacity for heat pumps. 1-ton is equal to 12,000 BTU/h

BTU: British Thermal Unit: The amount of heat required to raise the temperature of one pound of water by one degree Fahrenheit.

Margin: In the context of an electrical utility, it is the portion of the revenue that remains after subtracting all costs and expenses and is typically expressed as a percentage of total revenue.

GSHP: Ground Source Heat Pump

Non-coincidental Demand: The highest demand at any given time, usually measured in 24-hour increments or monthly increments.

Coincidental Demand: Demand measured during a defined time period; in the case of a Generation and Transmission System providing power to a cooperative, it is the highest peak load at the cooperative coincident with the highest peak load of the G&T.  Some utilities peak in the summer, while others are in the winter while others peak in both seasons.

Billing Demand: This is the Kilowatt Demand measured during the Coincident period and multiplied by a dollar value to arrive at the monthly billing demand component that is part of the G&T power bill to the Cooperative.

PF– Power Factor: This is a measurement of the efficiency of the device consuming electricity. 100% power factor is realized with all resistive-type loads, water heaters, space heaters, etc. Less than 100% power factors are realized with motor loads due to friction and drag on the motors.  Above 92% is acceptable. Below 92% power factors lead to unbalanced services and may require voltage regulators, capacitors, etc.

LF– Load Factor: This is a measurement of the efficiency of the total consumption of energy over a given period of time in relation to its potential consumption.  (Ex. If a 1000-watt (1 kW) device consumes 1 kWh of energy in a one-hour period, it has a 100% load factor.  If a 1 kW device consumes .5 kWh in a one-hour period there is a 50% load factor, etc.)

Base Rate: – This is the portion of each kilowatt hour charge which is necessary to fully recover the cost of purchased power.  (Ex. If the base rate requires 6 cents per kilowatt hour sold to recover the total energy purchased on the wholesale power bill, and the published rate is 8 cents, it means the cooperative has 2 cents of each kilowatt hour left over for operating the cooperative because 6 cents is needed to pay for power purchased.  If a month occurs when the purchased power needs 7 cents recovery, it will reduce the margin from 2 cents to 1 cent leaving the cooperative short of its operational needs.  A power cost adjustment of 1 cent would then be added to the 8 cents so the cooperative remains whole on its operational needs.  The reverse of that is true if the wholesale cost of power drops below 6 cents per kWh.  The power cost adjustment would be a negative factor.)

PCA – Power Cost Adjustment: This is an adjustment made to the published rates when the wholesale cost of power exceeds or falls short of being collected by the Base Rate.

MSF – Margin Stabilization Factor: This is a factor designed for multiple uses.  One use of this factor is to recover additional operating funds needed to meet lending ratio requirements in a year when the cooperative’s budget has been increased due to catastrophic storm costs, or mild weather or any situation occurring which may cause the cooperative to miss its ratio targets.  It is applied as an adjustment factor on each kilowatt consumed until the needed revenues have been achieved.  It is a short-term avoidance of a rate increase.  A second use is as a factor designed to recover temporary investment costs in programs such as demand control, geo loops, etc.

Gross Receipts: This is a tax collected by cooperatives in lieu of sales tax.  2% of total sales is added to a customer’s bill and collected on behalf of the Oklahoma Tax Commission and is passed on to schools.

Wholesale Cost of Power: This is the total cost of power from the cooperative’s power supplier before any markup is added and passed on to the customer by the cooperative.  Wholesale power cost consists of generation demand, transmission demand, distribution demand, energy, fuel and any other charges from the power provider.

CP Demand – Coincidental Peak Demand: This is the amount of total capacity needed by the cooperative at the time of maximum generation requirements by the wholesale power provider.

NCP Demand – Non-Coincidental Peak Demand: This is the point in time during a one-month period that represents the maximum total capacity needed by the cooperative, having no correlation with the maximum generation period of the power provider.

Load Control – Term given to the act of reducing or eliminating CP Demand during a time period which coincides with WFEC’s peak time periods, and which reduces the average wholesale cost of power to the cooperative as a result.

Fuel: This is a factor charged by the power provider that represents its rolling average cost of fuel for generation purposes.  It is applied on a per kilowatt hour basis.

Energy – This is a factor charged by the power provider that represents the cost of the generation equipment and its related expenses, to supply power to cooperatives.  This factor is charged on a per kilowatt hour basis and varies quarterly depending on the season. 

Mil: This is a number defined as 1/10th of a cent or .001.  If energy costs .00636 cents per kilowatt hour, then the energy cost is 6.36 mils.

Tariff: The officially recognized term for rates used by regulatory agencies.

Geo – Geothermal Heat Pump: Type of heating and cooling system which utilizes the stored energy capacity and capabilities of the earth to condition a home or business by means of water transference.

Air to Air – Air Source Heat Pump: Type of heating and cooling system which utilizes the energy that exists in the outdoor air to condition a home or business.

Learn more about the GeoHC Utility Margin Calculators

Name

Contact Us

Please fill out the form below and we will contact you as soon as possible.